- Insulation Materials & Elements[6]
- Other Waterproofing Materials[3]
- Other Wires[1]
- Antennas for Communications[5]
- Mobile Phone Stickers[3]
- Other Auto Parts[3]
- Aluminum Foil[1]
- Webbing[1]
- Other Wiring Accessories[3]
- Other Plastic Products[2]
- Other Electronic Accessories[4]
- Terminals[1]
- Other Electronic Components[1]
- Adhesive Tape[1]
- Cable Sleeves[1]
- Fiberglass Mesh[1]
- Contact Person : Ms. feng karen
- Company Name : Changchun Zhongke Applied Chemistry Materials Co., Ltd.
- Tel : 86-431-85832491,13804462192
- Fax : 86-431-85832497
- Address : Jilin,changchun,17-332,No.3355 Guigu Street,High&new Technology District,Chagnchun City
- Country/Region : China
- Zip : 130012
Insulation Sleeve
Item:HB1571 Insulation Sleeve
Features:
1) Live installation 2) Lightweight 3) Anti-tracking 4) Weather resistance 5) Superior UV and abrasion resistance 6) Localized installation 7) Range taking
Application:1)Quick installation The OLIS sleeve is a cold applied wrap around cover that provides retrofit insulationfor overhead conductors to help prevent electrical outages caused by incidentalcontact from tree branches or wildlife.
2)OLIS provides unique insulation protectsolution especially for railway overhead conductor.
3) The OLIS sleeve may be applied selectively on problem spans to avoid costly conductorreplacement.
4) Installation is possible on energized lines utilizing the OLIS tool which attaches directly to the overhead conductor and remains stationary ina single location.
5)If overhead lines get across trees or are close to trees orbuildings, it may lead to electrical outages caused by incidental contact fromtree branches or wildlife. CIAC Overhead Line Insulation Sleeves can provide uniqueinsulating protection solution for those kinds of problems.
6)CIAC Overhead LineInsulation Sleeves, used for railway contact network overhead line system, improveinsulating performance and prevent electrical outages caused by incidentalcontact from tree branches or wildlife.
Size:
Size | Suitable voltage | Suitable conductor section | Max.conductor diameter |
Φ18 | 1-15kv | 185mm2 | 18mm |
Φ18* | 1-35kv | >185mm2 | 18mm |
Φ20 | 1-15kv | 185mm2 | 22mm |
Φ20* | 1-35kv | 185mm2 | 22mm |
Φ28 | 1-15kv | 240mm2 | 30mm |
Φ28* | 1-35kv | 240mm2 | 30mm |
Φ38 | 1-15kv | >1000mm2 | 38mm |
Φ38* | 1-35kv | >1000mm2 | 38mm |
Technical data:
Property | Testing method | Typical data |
Tensile strength | GB/T 1040-92 | ≥10Mpa |
Elongation at break | GB/T 1040-92 | ≥500% |
Dielectric strength | GB/T 1408-89 | 20kv/mm |
Volume resistance | GB 1410-2006 | ≥1.0*1013Ω*cm |
Dielectric constant | GB 1409-2006 | ≤3.0 |
Flammability(Oi) | GB/T 2406-1993 | ≥27 |
Microtherm flexility(-40°C,4hrs) | ASTMD 2671 | No Crack |
Water absorption | GB/T 1034-98 | ≤0.5% |
Insulation Sleeve